Cart  |  Contact  |  Help  |  ininfo@dwyeromega.com  | 
Toll-Free in India 000 800 442 0175
International+65 6415 5353

Rangeable Wet/Wet Differential Pressure Transmitter

PX2310

Rangeable Wet/Wet Differential Pressure Transmitter
Low Differential pressure
 | PX2310

CE
  • Each Model has 4 Unidirectional and 4 Bi-Directional Ranges
  • 4 Selectable Outputs, 0 to 5 Vdc, 1 to 5 Vdc, 0 to 10 Vdc, 4 to 20 mA (2-Wire)
  • Jumper Selectable Hi/Lo Ports
  • 4-Digit LCD can Show Either Line or Differential Pressure
  • Pushbutton or Remote Zero
  • Rugged NEMA 4 Cast Aluminum Housing
  • Applications
  • Energy Management Systems
  • Process Control Systems
  • Flow Measurement
  • Liquid Level
  • Pressure Drops Across Filters
Pressure Transducers - View related products

Description

The PX2310 offers the user unprecedented flexibility allowing field selection of range, type of output and field zeroing. The user can also select which port is hi and lo via jumpers. The 4-digit display can also be set to read either line pressure or differential pressure. The entire package is rugged cast aluminum with a NEMA 4 rating and the solid state sensor offers excellent accuracy, stability, and low long term drift.

SPECIFICATIONS
Accuracy RSS Ranges A, B & C: ±1.0%
    Full Scale; Range D: ±2.0% RSS full scale
Storage Temperature: -20 to 85°C (-4 to 185°F)
Operating Temperature: -20 to 85°C (-4 to 185°F) (Limits of Electronics only)
Compensated Range: 0 to 54°C (32 to 130°F)
Zero Shift (Over Compensated Range): 2.0% full scale
Span Shift (Over Compensated Range): 2.0% full scale
Response Time: 1 to 5 seconds, selectable
Proof Pressure: 2.2 x full scale
Burst Pressure: 40 x full scale
Vibration: 10 g from 50 to 2000 Hz
Shock: 200 g
Excitation: 12 to 30 Vdc @ 5 mA (typical)/18 to 28 Vac 40 mA (typical) (reverse polarity protected)
Output User Selectable:
    Voltage: 0 to 5 Vdc, 0 to 10 Vdc, 1 to 5 Vdc 3-wire system
    Current: 4 to 20 mA 2-wire system (0 to 1000 Ω load)
Minimum Supply Voltage: Vdc = 12 + 0.2 x loop resistance
Maximum Supply Voltage: Vdc = 30 + 0.004 x loop resistance
Electrical Connection: ½ in conduit
Pressure Connection: 1/8 -18 NPT internal
Sensor Cavity Volume: 0.2 cc
Case: Die cast aluminum, powder coated
Environmental Protection: NEMA 4
Wetted Parts: 17-4 PH stainless steel (not recommended for hydrogen)
Dimensions: 102 L x 152 W x 51 mm diameter (4.0 x 6 x 2")
Place Order(Specify Model Number)
Part Number/Desc.
Qty
Description
PX2310-050DX
USD1,275.00
Availability: 5 weeks
 
Wet/wet differential transducer with 0-50 psid max range
PX2310-100DX
USD1,282.64
Availability: 5 weeks
 
Wet/wet differential transducer with 0-100 psid max range
PX2310-250DX
USD1,280.75
Availability: 9 weeks
 
Wet/wet differential transducer with 0-250 psid max range
All amounts shown in USD
Note: Comes complete with operator’s manual.
Ordering Example: (1) PX2310-100DX wet /wet differential transducer with six selectable ranges, USD1,282.64
We noticed you are from the US. Visit your local site for regional offers and live support.