Cart  |  Contact  |  Help  |  ininfo@dwyeromega.com  | 
Toll-Free in India 000 800 442 0175
International+65 6415 5353

Sanitary RTD Sensors with Integral Cables for use in CIP Clean-In-Place Applications

PRS-CB Series

Direct Immersion Sanitary RTD Sensors Pt100 with Integral Cables for Food, Dairy, Beverage and BioPharmaceutical Applications | PRS-CB Series

USD281.01 PRS-3-100-A-S-0300-D1-CB-120

  • 1/4" Diameter Probe Design for Standard Duty, or
    3/8" to 3/16" Stepped Probe Design For Heavy Duty Applications
  • Probe Lengths of 3", 4", 5" and 6" Available From Stock, Other Lengths Also Available
  • Process Connection is a 1½"-16 AMP Tri-Grip™ (Tri-Clamp® Compatible) Standard, Other Sizes and Styles Available. Flanges Conform to ASME BPE-2007 Standard to Assure Trouble Free Interchangeability.
  • Sensor Can be Used in Sanitary, Hygienic and Clean-In-Place Food, Dairy, Beverage and BioPharmaceutical Processes
  • 316L SS Wetted Surfaces with 32 µinch or Better Surface Finish
  • 4-Conductor, 120" Long PFA Cable with Molded Nylon Strain Relief Standard
  • -50 to 200°C (-58 to 392°F) Temperature Range
  • 4-Wire Pt100 Class A Platinum RTD Sensor (100.00±0.06Ω at 0°C) Standard
  • Compatible with 3-Wire and 2-Wire RTD Instruments and Transmitters
Sanitary - View related products

Description

Sanitary Temperature Sensor Specifications Include:
  • 316L stainless steel process wetted surfaces with surface finishes of 32 microinches or better.

  • Probe lengths of 3, 4, 5 or 6 inches available from stock, other lengths available as special orders.

  • Sensor Output is a 4-wire, 100 ohm, Class A, Platinum RTD meeting the requirements of IEC 60751.

  • These sensors can be used with 2-wire or 3-wire systems see information below.

  • Insulation resistance: 100 megohms minimum at 100 VDC.

  • Thermal response time of less than 2.5 seconds in water flowing at 3 ft/sec (63% response).


  • This Sanitary Temperature Sensor containes a PT100 Platinum RTD element and is designed for use in Food, Dairy, Beverage and BioPharmaceutical Clean-In-Place (CIP) type applications. The sensor includes a 1½" 16AMP process connection that conforms to ASME BPE-2007 for easy installation using industry standard gaskets and clamps. Standard Duty sensors are available with ¼" diameter probes, and Heavy Duty sensors are available with a stepped 38" to 316" diameter probe. This sensor is provided with a 120" long, 4-conductor, #26AWG stranded nickel plated copper, PFA insulated and jacketed cable with a strain relief for convenient connection to control or monitoring equipment.

    Food process hygienic temperature sensors can be used to aid food safety inspection compliance and verification of time temperature control. Combined with a chart recorder model CTXL you can temperature monitor a CCP ( Critical Control Point) or sanitation time and move toward a HACCP (Hazard Analysis Critical Control Point) compliance plan.

    In addition to the standard 1½-16AMP process connection, these can be provided in the following sizes and styles:
    Process ConnectionModel Number Code
    3/4"-16AMP-B1-
    1" and 1½"-16AMP-D1-
    2"-16AMP-E1-
    2½"-16AMP-F1-
    3"-16AMP-G1-
    4"-16AMP-H1-










    If you need a process connection that is not listed above, please contact our sales department for availability.

    These sanitary sensors are supplied standard as 4-wire assemblies with two red wires and two white wires. When used in 3-wire applications, cut off one white wire making sure that it will not contact any terminals or metal surfaces (note: twisting the two white wires together will reduce the lead wire resistance on one side of the sensing element by half adversely affecting the accuracy of the reading). When used in 2-wire applications, cut off one white wire and one red wire (note: in 2-wire applications, twisting the two same-colored wires together at the terminals will not adversely affect your sensor accuracy since both wires will be affected by the reduction in resistance).

    These sensors are also available in Thermistor and Thermocouple styles to accommodate any process input requirement.
    Place Order(Specify Model Number)
    Part Number/Desc.
    Qty
    Description
    Standard Duty ¼' Diameter Probe Design
    PRS-3-100-A-S-0300-D1-CB-120
    USD281.01
    Availability: 6 weeks
     
    3' long standard duty probe
    PRS-3-100-A-S-0400-D1-CB-120
    USD276.00
    Availability: 6 weeks
     
    4' long standard duty probe
    PRS-3-100-A-S-0500-D1-CB-120
    USD276.00
    Availability: 6 weeks
     
    5' long standard duty probe
    PRS-3-100-A-S-0600-D1-CB-120
    USD276.00
    Availability: 6 weeks
     
    6' long standard duty probe
    Heavy Duty 3/8' to 3/16' Stepped Probe Design
    PRS-3-100-A-H-0300-D1-CB-120
    USD341.00
    Availability: 6 weeks
     
    3' long heavy duty probe
    PRS-3-100-A-H-0400-D1-CB-120
    USD341.00
    Availability: 6 weeks
     
    4' long heavy duty probe
    PRS-3-100-A-H-0500-D1-CB-120
    USD341.00
    Availability: 6 weeks
     
    5' long heavy duty probe
    PRS-3-100-A-H-0600-D1-CB-120
    USD341.00
    Availability: 6 weeks
     
    6' long heavy duty probe

    Order By Part Number

    Part Number
    Qty
    Part Number
    Qty


    All amounts shown in USD
    Note:
  • For standard duty probe lengths longer than 6", change "-0600" in model number to the required length (example: 12" = "-1200", 9¼" = "-0925") and add $1 per inch to the price (up to 24 inches).
  • For heavy duty probe lengths longer than 6", change "-0600" in model number to the required length (example: 12" = "-1200", 9¼" = "-0925") and add $2.50 per inch to the price (up to 24 inches).
  • For other than the standard 1½-16AMP process connection, change "-D1-" in the model number to the code for the alternate process connection option listed above the "To Order" table and add $20 to the price
  • For cable lengths longer than 10' (120"), change the "-120" in model number to the desired length in inches and add $1 per foot to the price.
  • For probe lengths longer than 24 inches please contact Customer Service.


  • Ordering Example: (1) PRS-3-100-A-S-0400-D1-CB-120 Sanitary RTD sensor with 4-wire Pt100, Class A accuracy element, ¼'' diameter probe 4'' long with 1½'', 16AMP mounting cap and integral 120 inch long, 4-conductor cable with strain relief, USD276.00

    Part Number Builder

    Build Your Part Number Below
    Option Descriptions:


    (1) Nominal Element Resistance select from:
    100 for 100 ohm @ 0 C (standard)
    1000 for 1 kohm @ 0 C

    (2) Accuracy select from:
    A for Class A Accuracy

    (3) Probe Diameter select from:
    S for Standard Duty 1/4 inch
    H for Heavy Duty 3/8 to 3/16 inch stepped probe

    (4) Probe Length select from:
    0300 for 3 inch length
    0400 for 4 inch length
    0500 for 5 inch length
    0600 for 6 inch length

    (5) Sanitary Flange (Cap) Size select from:
    D1 for 1-1/2 inch Tri-Grip Flange (standard)
    B1 for 3/4 inch 16AMP Tri-Grip Flange
    E1 for 2 inch 16AMP Tri-Grip Flange
    F1 for 2-1/2 inch 16AMP Tri-Grip Flange
    G1 for 3 inch 16AMP Tri-Grip Flange
    H1 for 4 inch 16AMP Tri-Grip Flange

    (6) Lead Wire Cable Length select from:
    120 for 120 inch/10 ft (standard)
    144 for 144 inch/12 ft
    180 for 180 inch/15 ft
    240 for 240 inch/20 ft
    Note: All combinations may not be valid, check spec sheet for valid part numbers.
    We noticed you are from the US. Visit your local site for regional offers and live support.