Cart  |  Contact  |  Help  |  ininfo@dwyeromega.com  | 
Toll-Free in India 000 800 442 0175
International+65 6415 5353

hot point™ Dry Block Probe Calibrator

CL900 and CL950 Series

Dry Block Probe Temperature Calibrator | CL900 and CL950 Series

Dry Block Probe Temperature Calibrator

USD6,761.98 CL900-110

  • Calibrates Thermocouples and RTD’s in Seconds
  • Highly Accurate 0.9°C (1.5°F) & Exceptional Stability (0.3°F) for Precision Calibrations
  • Completely Portable for Factory, Laboratory and Instrument Shops
  • Interchangeable Test Wells and CL950 Built-In 5 Port Well Design Provides Customer Flexibility
  • Wide Temperature Range 40°F Above Ambient to 900°F (482°C) Covers Most Industrial Applications
  • NIST Calibration Available
Calibration Equipment - View related products

Description

OMEGA’s new hot point® calibrators allow calibration of thermocouple and RTD probes quickly and easily with accuracy to 0.9°C (1.5°F). An integral RTD sensor assures high measurement accuracy and repeatability. A built-in microprocessor-based PID digital controller assures exceptional stability. Setpoint and actual temperature are displayed simultaneously. Temperature can be set in one-degree increments from 22°C (40°F) above ambient to 482°C (900°F).

The CL900 calibrator accepts a variety of standard and metric optional inserts which are available in 4" and 6" depths and for probe diameters from 1/8" to 3/8". An undrilled insert is also available. The CL900 comes complete with a 1/4" diameter, 6" deep insert well and insert block tongs. Additional inserts can be ordered separately as required for other diameter probes. 6" depth inserts are used for probes 7" and longer; 4" depth inserts are used for probes 5" and longer.

The CL950 calibrator features a built-in well with 5 ports sized to accommodate a 1/16", 1/8", 3/16", and two 1/4" diameter probes. The multi-port design allows for the use of a calibrated or NIST-traceable probe and meter to be used as a standard while calibrating other probes. The 5 port design also allows for calibration of more than one probe at a time, and eliminates the need for separate insert wells.

Inserts for CL900 Series
Model No. Description
CL901 Insert, 1/8 dia. x 4" deep test well
CL901-M Metric insert, 2 dia. x 101.6 mm deep test well
CL902 Insert, 1/8 dia. x 6" deep test well
CL902-M Metric insert, 2 dia. x 152.4 mm deep test well
CL903 Insert, 3/16 dia. x 4" deep test well
CL903-M Metric insert, 3 dia. x 101.6 mm deep test well
CL904 Insert, 3/16 dia. x 6" deep test well
CL904-M Metric insert, 3 dia. x 152.4 mm deep test well
CL905 Insert, 1/4 dia. x 4" deep test well
CL905-M Metric insert, 4.5 dia. x 101.6 mm deep test well
CL906 Insert, 1/4 dia. x 6" deep test well
CL906-M Metric insert, 4.5 dia. x 152.4 mm deep test well
CL907 Insert, 5/16 dia. x 4" deep test well
CL907-M Metric insert, 6 dia. x 101.6 mm deep test well
CL908 Insert, 5/16 dia. x 6" deep test well
CL908-M Metric insert, 6 dia. x 152.4 mm deep test well
CL909 Insert, 3/8 dia. x 4" deep test well
CL910 Insert, 3/8 dia. x 6" deep test well
CL911 Insert, undrilled
Specifications
(All specifications are based on the test probes being in contact with the bottom of the test well)

Temperature Range: Ambient +22 to 482°C (+40 to 900°F)
Operating Ambient Temperature Range: 5°C to 38°C (40°F to 100°F)
Accuracy: (1°F resolution)
CL900 with 6" test well inserts: ±1.5°F ±1 LSD.
CL900 with 4" test well inserts: ±3°F ±1 LSD.
CL950: ±1.5°F, ±1 LSD.
Control Stability: ±0.3°F or better
Temperature Uniformity (within the bottom 1" of the test well):
CL900:
with 6" test well inserts: 0.3%
with 4" test well inserts: ±0.4%.
CL950: ±0.3%
Max. Probe Immersion:
CL900:
with 6" test well inserts: 150 mm (6")
with 4" test well inserts: 100 mm (4").
CL950: 150 mm (6")
Control: Microprocessor-based PID digital controller with data retention
Power: 110-125 Vac, 50/60 Hz, 1050 watts; 220 Vac, 50/60 Hz, 1050 watts
Dimensions: 300 H x 216 W x 311 mm D (11.75 x 8.5 x 12.25")
Weight: 10.1 kg (22.3 lb)

CL900-110 hot point™ dry block calibrator
CL900-110 hot point™ dry block calibrator, with DSS-460-K benchtop thermometer, calibrating a single thermocouple probe, shown smaller than actual size.
multi-well accepts up to 5 probes at one time
CL950 multi-well accepts up to 5 probes at one time and comes standard with 1/16, 1/8, 3/16 and two 1/4" diameter holes.
multi-well accepts up to 5 probes at one time
CL900 accepts any insert listed in the table above.
Place Order(Specify Model Number)
Part Number/Desc.
Qty
Description
Hot Point® Calibrators
CL900-110
USD6,761.98
Availability: 7 weeks
 
hot point™ calibrator, 110 Vac
CL900-220
USD6,630.00
Availability: 7 weeks
 
hot point™ calibrator, 220 Vac
CL950-110
Consult Sales  
Availability: 
 
 
Multi-well hot point™ 110 V
CL950-220
Consult Sales  
Availability: 
 
 
Multi-well hot point™ 220 V
Inserts for CL900 Series
CL901
USD189.00
Availability: 4 weeks
 
Insert, 1/8" dia. x 4" deep test well
CL901-M
USD189.00
Availability: 4 weeks
 
Metric insert, 2 mm dia. x 106.6 mm deep test well
CL902
USD193.20
Availability: 4 weeks
 
Insert, 1/8" dia. x 6" deep test well
CL902-M
USD189.00
Availability: 4 weeks
 
Metric insert, 2 mm dia. x 152.4 mm deep test well
CL903
USD189.00
Availability: 1 week
 
Insert, 3/16" dia. x 4" deep test well
CL903-M
USD189.00
Availability: 4 weeks
 
Metric insert, 3 mm dia. x 106.6 mm deep test well
CL904
USD189.00
Availability: 1 week
 
Insert, 3/16" dia. x 6" deep test well
CL904-M
USD193.20
Availability: 4 weeks
 
Metric insert, 3 mm dia. x 152.4 mm deep test well
CL905
USD189.00
Availability: 1 week
 
Insert, 1/4" dia. x 4" deep test well
CL905-M
USD189.00
Availability: 4 weeks
 
Metric insert, 4.5 mm dia. x 106.6 mm deep test well
CL906
USD189.00
Availability: 1 week
 
Insert, 1/4" dia. x 6" deep test well
CL906-M
USD189.00
Availability: 4 weeks
 
Metric insert, 4.5 mm dia. x 152.4 mm deep test well
CL907
USD189.00
Availability: 1 week
 
Insert, 5/16" dia. x 4" deep test well
CL907-M
USD189.00
Availability: 4 weeks
 
Metric insert, 6 mm dia. x 106.6 mm deep test well
CL908
USD193.20
Availability: 4 weeks
 
Insert, 5/16" dia. x 6" deep test well
CL908-M
USD193.20
Availability: 4 weeks
 
Metric insert, 6 mm dia. x 106.6 mm deep test well
CL909
USD189.00
Availability: 4 weeks
 
Insert, 3/8" dia. x 4" deep test well
CL910
USD193.20
Availability: 4 weeks
 
Insert, 3/8" dia. x 6" deep test well
CL911
USD169.42
Availability: 1 week
 
Insert, undrilled
All amounts shown in USD
Note: Comes with complete operator's manual. Inserts are for CL900 and CL900A hot point® calibrators only. To order NIST Calibration points add suffix “-NIST” to model number and $175 to price.
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Ordering Example: (1) CL900-110 hot point™ calibrator, 110 Vac, USD6,761.98
We noticed you are from the US. Visit your local site for regional offers and live support.