Cart  |  Contact  |  Help  |  ininfo@dwyeromega.com  | 
Toll-Free in India 000 800 442 0175
International+65 6415 5353

Preamplified Alpha® Electrodes

PHE-6300, PHE-5300, PHE-2114 and PHE-1304

Preamplified Alpha® Electrodes | PHE-6300, PHE-5300, PHE-2114 and PHE-1304

Preamplified Alpha® Electrodes

USD168.05 PHE-1304-EB

  • 16 Month Shelf Life
  • Interfaces Directly with Most Instrumentation that Accepts mV Input Signal
  • Signal can be Run Up to 305 m (1000')
  • Power Supply Available in Three Styles
pH Field and Laboratory Electrodes - View related products

Description

OMEGA Engineering offers pH electrodes with integral preamplifiers for laboratory or industrial applications. These electrodes can interface directly with equipment that accepts a millivolt input signal with a 10 k½ or greater input impedance, such as a data acquisition interface or multimeter. The preamplifier converts the high impedance millivolt signal of the electrode into a low impedance signal, enabling the signal to be run up to 305 m (1000') without signal loss. The electrode is supplied with 1 to 3 m (3 to 10') of coaxial cable, depending on the model. If longer cable lengths are required, simply splice on extension cable.

These preamplified electrodes are available in a variety of styles and can interface with any pH meter, controller, transmitter, multimeter or data acquisition system with a one-to-one unity gain.

The preamplified power option comes in styles: an encapsulated battery design, suffix "-PB", an external battery style, suffix "-EB", and a style for use with an external dc power source, "-NB".
To order a preamplified electrode see the To Order guide below.

Model No. Description
PHE-1304-(*)Combination gel-filled, epoxy-bodied, general purpose laboratory
pH electrode. pH range 0 to 12, temp. 0 to 80°C (32 to 176°F).
PHE-2114-(*)Combination general purpose, large bulb, refillable glass pH
electrode. pH range 0 to 13, temp. 0 to 100°C (32 to 212).
PHE-5311-10-(*)Industrial in-line combination, general purpose, gel filled, pH
electrode, Kynar housing, 1/2" MNPT threading, insertion length 1".
10' of cable standard. pH range 0 to 13, temp. range
-5 to 100°C. (23 to 212°F). Dimensions: 127 x 25 mm (5 x 1").
PHE-5411-10-(*)Industrial in-line combination double junction electrode. MNPT
threading, insertion length 1". 10' of cable standard. pH range 0 to
13, temp. range -5 to 100°C (23 to 212°F).
Dimensions: 127 x 25 mm (5 x 1").
PHE-5316-10-(*)Industrial in-line combination, general purpose, gel-filled, pH
electrode, CPCV housing, 3/4" MNPT threading, 2" insertion length.
10' cable standard. pH range 0 to 13, temp. range
-5 to 80°C (23 to 176°F). Dimensions: 168 x 25 mm (6.6 x 1").
PHE-6351-10-(*)Industrial submersible, combination, general purpose,
gel-filled, pH electrode. Electrode potted in 36" ABS pipe.
10' cable standard. pH range 0 to 13, temp. range 0 to 80°C
(32 to 176°F). Dimensions: 28 x 914 mm (1.1 x 36").
PHE-6451-10-(*)Industrial submersible, combination, double junction,
gel-filled, pH electrode. Electrode potted in 36" ABS pipe.
10' cable standard. pH range 0 to 13, temp. range
0 to 80°C (32 to 176°F). Dimensions: 28 x 914 mm (1.1 x 36").
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
Example part numbers are shown below. For additional configurations see the Part Number Builder below this table.
Click to expand/minimize a list of what others bought with thePHE-1304
PHE-1304
USD69.99
Availability: 4 weeks
 
Combination gel-filled, epoxy-bodied, general purpose laboratory pH electrode. pH range 0 to 12 temp. 0 to 80°C (32 to 176°F)
  
PHE-1304-EB
USD168.05
Availability: 6 weeks
 
Pre-amp electrode with replaceable external battery pack
  
PHE-5311-10
USD205.00
Availability: 6 weeks
 
Industrial in-line combination, general purpose, gel-filled, pH electrode, PVDF housing, 1/2 MNPT threading, insertion length 1". pH range 0 to 13, temperature range -5 to 100°C (23 to 212°F)
  
PHE-5311-10-EB
USD309.00
Availability: 6 weeks
 
Pre-amp electrode with replaceable external battery pack
  
PHE-5311-10-NB
USD288.00
Availability: 6 weeks
 
Pre-amp electrode, requires external DC power supply
  
PHE-5311-10-PT1K
USD288.00
Availability: 6 weeks
 
Industrial in-line combination, general purpose, gel filled, pH electrode with 1000Ω Platinum RTD
  
PHE-5411-10
USD248.00
Availability: 6 weeks
 
Industrial in-line combination double junction electrode, MNPT threading, insertion length 1". pH range 0 to 13, temperature range -5 to 100°C (23 - 212°F)
  
PHE-5411-10-NB
USD328.00
Availability: 6 weeks
 
Pre-amp electrode, requires external DC power supply
  
PHE-5411-10-PT1K
USD328.00
Availability: 6 weeks
 
Industrial in-line combination double junction electrode with 1000Ω Platinum RTD
  
PHE-5316-10
USD184.00
Availability: 6 weeks
 
Industrial in-line combination, general purpose, gel-filled pH electrode, CPCV housing, 3/4 MNPT threading, 2" insertionlength. pH range 0 to 13, temperature range -5 to 80°C (23 to 176°F)
  
PHE-5316-10-PT100
USD268.00
Availability: 6 weeks
 
Industrial in-line combination, general purpose, electrode with 100 Ω Platinum RTD
  
PHE-5316-10-PT1K
USD268.00
Availability: 6 weeks
 
Industrial in-line combination, general purpose, electrode with 1000Ω Platinum RTD
  
PHE-6351-10
USD230.00
Availability: 6 weeks
 
Industrial subersible, combination, general purpose gel-filled, pH electrode. pH range 0 to 13, temperature range 0 to 80°C (32 to 176°F)
  
PHE-6351-10-NB
USD312.00
Availability: 6 weeks
 
Pre-amp electrode, requires external DC power supply
  
PHE-6351-10-PT100
Consult Sales  
Availability: 
 
 
Industrial submersible, combination, general purpose gel-filled, pH electrode with 100Ω Platinum RTD
  
PHE-6351-10-PT1K
USD312.00
Availability: 6 weeks
 
Industrial submersible, combination, general purpose gel-filled, pH electrode with 1000Ω Platinum RTD
  
PHE-6451-10
USD268.52
Availability: 6 weeks
 
Industrial submersible, combination, double junction, gel-filled, pH electrode. pH range 0 to 13, temperature range 0 to 80°C (32 to 176°F)
Accessories
  
EB-SPARE
USD37.00
Availability: 7 weeks
 
Spare battery pack for -EB option.
Click to expand/minimize a list of what others bought with thePHE-DPS
PHE-DPS
USD97.00
Availability: 6 weeks
 
±3 Vdc power supply to operate preamplified electrodes, input 115 Vac
Click to expand/minimize a list of what others bought with thePHA-10
PHA-10
USD22.39
Availability: 1 week
 
pH 10 buffer solution, 500 ml (1 pt)
Click to expand/minimize a list of what others bought with thePHA-10-GAL
PHA-10-GAL
USD55.93
Availability: 1 week
 
pH 10 buffer solution, 4L (1 gal)
Click to expand/minimize a list of what others bought with thePHA-4
PHA-4
USD21.19
Availability: 1 week
 
pH 4 buffer solution, 500 ml (1 pt)
Click to expand/minimize a list of what others bought with thePHA-4-GAL
PHA-4-GAL
USD52.94
Availability: 1 week
 
pH 4 buffer solution, 4L (1 gal)
Click to expand/minimize a list of what others bought with thePHA-7
PHA-7
USD21.19
Availability: 1 week
 
pH 7 buffer solution, 500 ml (1 pt)
Click to expand/minimize a list of what others bought with thePHA-7-GAL
PHA-7-GAL
USD52.94
Availability: 2 weeks
 
pH 7 buffer solution, 4L (1 gal)
Click to expand/minimize a list of what others bought with thePHA-DI
PHA-DI
USD25.06
Availability: 1 week
 
De-ionized water, 500 ml (1 pt)
Click to expand/minimize a list of what others bought with thePHA-DI-GAL
PHA-DI-GAL
USD62.62
Availability: 1 week
 
De-ionized water, 4L (1 gal)
  
PHAB-DI
USD57.00
Availability: 3 weeks
 
20 single use foil packets of de-ionized water
Click to expand/minimize a list of what others bought with thePHAB-PH
PHAB-PH
USD56.82
Availability: 1 week
 
5 each single use foil packets of pH-4, pH-7, pH-10, and de-ionized water
All amounts shown in USD
Note: Comes complete with 1 to 3m (3 to 10') of cable and electrode care instruction sheet.

For non-standard cable lengths, replace te suffix "-10" with the desired length in feet; add $2 per foot. (Additional cost of $2 per foot applies to the entire cable length).


Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Code in Part Number select from:
1304 for code 1304
2114 for code 2114
5311-10 for code 5311-10
5316-10 for code 5316-10
6351-10 for code 6351-10
6451-10 for code 6451-10

(2) Code in Part Number select from:
Nothing(leave field blank)
-EB for Replaceable external battery pack
-PB for Battery encapsulated in the cap of the electrode. Battery life approximately one year. Battery cannot be replaced
-NB for Requires external dc power supply of ±1.5 Vdc to ±9 Vdc
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.