High Speed Fiber Optic Infrared Transmitter

OS4000 Series

Fiber Optic Infrared Transmitter | OS4000 Series

Fiber Optic Infrared Transmitter

  • High Speed Response Time of 1 msec
  • 3 Standard Optical Field of Views
  • Emissivity Adjustable from 0.05 to 0.99
  • 4 Standard Analog Outputs
  • RS-232 PC Interface with Windows® Based Data Logging Software
  • Built-In Laser Sighting For Target Alignment
  • Mounting Bracket and Mounting Nuts are Included
  • Optional Water Cool Jacket Accessory
  • Optional Built-In Relays with Contact Closure Output
  • Optional Custom Optical Field of Views and Temperature Ranges
Process Measurement and Control Instruments - View related products

Description

The OS4000 series high speed industrial fiber optic infrared transmitters measure temperature ranges from 200 to 1600ºC (392 to 2912°F) using three standard optical fields of view and three standard fiber optic cable lengths. This unit offers many standard features such as adjustable Emissivity, linear analog output, high and low alarm voltage output, RS232 PC interface, built-in laser sighting, etc. Through Windows based PC interface software, the user can select response time, Peak-Hold function, high and low alarm set points, and data logging. This unit is packaged in a space saving of 2.5" OD by 6" long. The mounting bracket and two mounting nuts are included.

PC Interface Software
The OS4000 series comes with a Windows® based PC interface software. The software runs on Windows 2000, XP and Vista. The software allows the user to do the following:
  • Establish communication with the OS4001 and display temperature in real time both digitally and graphically
  • Select sound, COM port, and temperature engineering unit
  • Select the response time, and high and low alarm set points, and peak hold functions
  • Select chart scale either manual or automatic and chart time base
  • Display the temperature vs. time along with high and low alarm lines
  • Save the temperature data to a file
SPECIFICATIONS
Power:
15 to 24 Vdc
Temp Range: 100 to 1600°C (212 to 2912°F)
Accuracy: 1% of Rdg
Lens Probe Optical Field of Views:
    5.6 @ 203 mm (0.22" @ 8")
    2.2 @ 127 mm (0.086" @ 5")
    0.63 @ 51 mm (0.025" @ 2")
Fiber Optic Cable Lengths: 0.3, 0.9, 1.8, 3 m (1, 3, 6, 10')
Emissivity: 0.05 to 0.99 adjustable
Time Constant (0 to 63% Final Value): 1 msec (default) up to 3.2 seconds (programmable via PC software)
Peak and Hold: Programmable via PC software
    Holding Time: 1 to 60 seconds
Sample and Hold: Programmable via PC software
    Holding Time: 25 msec to 3.2 seconds
Spectral Response: 1.2 to 2.6 microns
Infrared Detector: InGaAs photo detector
Analog Output: 0 to 5 Vdc, 0 to 10 Vdc, 4 to 20 mA, 1 mV/Deg
PC Communication: RS232, 2-way
Alarm Set Points: High and low programmable via PC software
Alarm Output: Two voltage outputs, 30 mA drive
Optional Built-in Relay: Two 10A @ 24 Vdc SPST NO relays (high and low)
Operating Ambient Temperature:
    Transmitter: 0 to 50°C (32 to 122°F)
    Fiber Optic Lens Assembly: 0 to 150°C (32 to 302°F)
    Polymer Bolt Probe: Tip (425°C max), bolt (150°C)
    Glass Tip Assembly: Tip (425°C max), fiber junction (150°C)
    Quartz Tip Assembly: Tip (1000°C max), fiber junction (150°C)
Glass or Quartz Rod Diameter: 0.080"
Glass Tip Field of view: 1.2 (Distance to Spot size)
Quartz Tip Field of view: 1.8 (Distance to Spot size) Laser Sighting
Maximum Laser Power Output: Less than 1 mW Laser Beam Wavelength (Color): 650 nm (red)
FDA Classification: Class II
European Classification: Class 2
Beam Diameter: 5 mm (0.20")
Dimensions:
    Transmitter: 63.5 OD x 152.4 mm L (2.5 x 6")
    Lens Probe: 25.4 OD x 190.5 mm L (1 x 7.5")
    Weight: 900 g (2 lbs)

Note: The head and cable must be calibrated as a pair, so order the Head and cable at the same time.

Read the High Speed Fiber Optic Infrared Transmitter Article for additional information.
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
Infrared Fiber Optic Transmitters
  
OS4001-MV
Consult Sales  
Availability: 
 
 
Infrared fiber optic transmitter, 1 mV/Degree output
  
OS4001-MV-AL
Consult Sales  
Availability: 
 
 
Infrared fiber optic transmitter, 1 mV/ Degree output with two built-in relays with contact closure output
  
OS4001-V1
Consult Sales  
Availability: 
 
 
Infrared fiber optic transmitter, 0 to 5 Vdc output
  
OS4001-V1-AL
Consult Sales  
Availability: 
 
 
Infrared fiber optic transmitter, 0 to 5 Vdc output with two built-in relays with contact closure output
  
OS4001-V2
Consult Sales  
Availability: 
 
 
Infrared fiber optic transmitter, 0 to 10 Vdc output
  
OS4001-V2-AL
Consult Sales  
Availability: 
 
 
Infrared fiber optic transmitter, 0 to 10 Vdc output with two built-in relays with contact closure output
  
OS4001-MA
Consult Sales  
Availability: 
 
 
Infrared fiber optic transmitter, 4 to 20 mA output
  
OS4001-MA-AL
Consult Sales  
Availability: 
 
 
Infrared fiber optic transmitter, 4 to 20 mA output with two built-in relays with contact closure output
Fiber Optic Lens Assemblies
Note: Transmitter and Cable must Calibrated as a pair so order cable at the same time as the Transmitter.
  
L1-7-3-1
Consult Sales  
Availability: 
 
 
200 to 800°C (392 to 1472°F) range, 3 ft. fiber cable with 0.22" @ 8" spot size
  
L1-7-6-2
Consult Sales  
Availability: 
 
 
250 to 1000°C (482 to 1832°F) range, 6 ft. fiber cable with 0.22" @ 8" spot size
  
L1-7-10-3
Consult Sales  
Availability: 
 
 
300 to 1200°C (572 to 2192°F) range, 10 ft. fiber cable with 0.22" @ 8" spot size
  
L1-2-3-2
Consult Sales  
Availability: 
 
 
250 to 1000°C (482 to 1832°F) range, 3 ft. fiber cable with 0.086" @ 5" spot size
  
L1-2-6-3
Consult Sales  
Availability: 
 
 
300 to 1200°C (572 to 2192°F) range, 6 ft. fiber cable with 0.086" @ 5" spot size
  
L1-2-10-4
Consult Sales  
Availability: 
 
 
350 to 1400°C (662 to 2552°F), 10 ft. fiber cable with 0.086" @ 5" spot size
  
L1-2-3-3
Consult Sales  
Availability: 
 
 
300 to 1200°C (572 to 2192°F), 3 ft. fiber cable with 0.025" @ 2" spot size
  
L1-2-6-4
Consult Sales  
Availability: 
 
 
350 to 1400°C (662 to 2552°F), 6 ft. fiber cable with 0.025" @ 2" spot size
  
L1-2-10-5
Consult Sales  
Availability: 
 
 
400 to 1600°C (752 to 2912°F) range, 10 ft. fiber cable with 0.025" @ 2" spot size
Accessories
  
OS4000-WC
Consult Sales  
Availability: 
 
 
Water cool jacket
  
L1-MB
Consult Sales  
Availability: 
 
 
Mounting bracket for fiber optic lens assembly
  
L1-AP
Consult Sales  
Availability: 
 
 
Air purge collar for fiber optic lens assembly
  
OS4000-VB-500
Consult Sales  
Availability: 
 
 
Vacuum bushing, 0.5" OD
Click to expand/minimize a list of what others bought with theTX8-100
TX8-100
USD190.56
Availability: 7 weeks
 
8 conductor shielded cable, 30 m (100')
Click to expand/minimize a list of what others bought with thePSR-24S
PSR-24S
Consult Sales  
Availability: 
 
 
Regulated 24 Vdc @ 400 mA power supply, screw terminals
Click to expand/minimize a list of what others bought with thePSR-24L
PSR-24L
Consult Sales  
Availability: 
 
 
Regulated 24 Vdc @ 400 mA power supply, stripped leads
Click to expand/minimize a list of what others bought with theWRS232-USB
WRS232-USB
USD521.34
Availability: 1 week
 
Wireless RS232 to USB transceiver
Click to expand/minimize a list of what others bought with theWUSB
WUSB
USD193.00
Availability: 1 week
 
Wireless USB receiver
All amounts shown in USD
Note:
* When ordering vacuum bushing, please specify the fiber cable length on both sides of the bushing.
 

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Output select from:
MV for 1 mV/Deg output
V1 for 0 to 5 Vdc output
V2 for 0 to 10 Vdc output
MA for 4 to 20 mA output

(2) Additional Option select from:
Nothing(leave field blank) for None
-AL for Two built-in relays with contact closure output
Note: All combinations may not be valid, check spec sheet for valid part numbers.