Cart  |  Contact  |  Help  |  ininfo@dwyeromega.com  | 
Toll-Free in India 000 800 442 0175
International+65 6415 5353

Coriolis Mass Flow Meter

FMC-5000

Coriolis Flow Meters | Mass Flow Meters | OMEGA | FMC-5000

Coriolis Flow Meters | Mass Flow Meters | OMEGA

CE
  • Mass Flow Rate, Volume, Density and Temperature Measurements
  • Rugged Meters with No Moving Parts Results in Minimal Maintenance
  • Accuracy Over a Wide Flow Range From a Single Meter Optimizes Plant Efficiency
  • No Flow Conditioning or Straight Pipe Runs Required, Making Installation Simplified and Less Expensive
Electronic Mass Flow Meters & Controllers - View related products

Description

The FMC-5000 Coriolis Mass Flow Meter is designed according to the Coriolis Force Principle. It is widely used for flow measurements and custody transfer in many industries such as petroleum, petrochemical, chemical, pharmaceutical, pulp and paper, food and dairy, and more. As an advanced flow and density measurement instrument, it is widely used in the measurement of liquids, gases and slurries, and garners a high reputation among customers around the globe. Coriolis meters are typically used in applications like batch control, blending, filling, dosing, custody transfer, process gas measurements, and more.

The FMC-5000 Series Coriolis Meter is designed according to the principle of Coriolis force. Under the alternating current effect, the electromagnetic coils mounted on the measuring tube will make two parallel measuring tubes vibrating at a certain fixed frequency. Whenever mass (either liquid or gas) flows through the measuring tubes, Coriolis force is generated, causing a “bending” or “deflection” in the top of the tubes. This deflection is sensed as a phase shift between two electronic pick-ups mounted on the tubes. The degree of phase shift is directly proportional to the mass flow within the tubes. The mass flow rate can be calculated by detecting the phase shift of the tubes. The temperature is also measured and used for compensation.



Specifications
Flow Range: See charts below
Connection: ANSI, DIN, JIS, or Sanitary Tri-Clamp flanges
Maximum Pressure: 16 bar (230 psi), [Optional: 25 bar (360 psi), 40 bar (580 psi) and 63 bar (913.7 psi)]
Body Material: 304 Stainless Steel
Measuring Tube Material: 316 L SS
Process Temperature Range:
    Integrate Type: -50 to 125°C (-58 to 257°F)
    Remote Type (-R): -50 to 200°C (-58 to 392°F)
Ambient Temperature: -40 to 55°C (-40 to 131°F)
Working Humidity: (5 to 95%) RH at 25°C (77°F)
Flow Accuracy/Repeatability:
    FMC-5100: 0.1/0.05% (Liquid Only)
    FMC-5200: 0.2/0.1% (Liquid Only)
    FMC-5500: 0.5/0.25%
Density Measuring:
    Range: 0.2 to 3.0 g/cm3
    Error: ± 0.002 g/cm3
    Repeatability: 0.001 g/cm3
Temperature Accuracy: ±1.0°C
Protection: NEMA 4X (IP65)
Approvals: CE, RoHS
Communications: RS485 (RTU Modbus®), HART® (-HART option)
Pulse Output: 0 to 10 kHz, ± 0.075% Full Scale
Current Output: 4 to 20 mA, 0.005% Full Scale
Power Supply: 18 to 36 Vdc, 85 to 265 Vac (-AC option), 15 W
Place Order(Specify Model Number)
Part Number/Desc.
Qty
Description
Compact Liquid Coriolis Meters with 0.5% Accuracy
FMC-5501LA
USD6,784.09
Availability: 4 weeks
 
Mounting ½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5502LA
USD7,950.00
Availability: 1 week
 
Mounting 1" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5503LA
USD8,940.00
Availability: 4 weeks
 
Mounting 1½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5504LA
USD11,485.00
Availability: 14 weeks
 
Mounting 2" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5505LA
USD15,075.00
Availability: 15 weeks
 
Mounting 3" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5506LA
USD24,190.00
Availability: 15 weeks
 
Mounting 4" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5507LA
USD30,960.00
Availability: 15 weeks
 
Mounting 6" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
Compact Liquid Coriolis Meters with 0.2% Accuracy
FMC-5201LA
USD8,130.00
Availability: 9 weeks
 
Mounting ½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5202LA
USD9,300.00
Availability: 9 weeks
 
Mounting 1" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5203LA
USD10,390.00
Availability: 9 weeks
 
Mounting 1½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5204LA
USD13,895.00
Availability: 9 weeks
 
Mounting 2" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5205LA
USD18,520.00
Availability: 15 weeks
 
Mounting 3" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5206LA
USD28,760.00
Availability: 15 weeks
 
Mounting 4" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5207LA
USD37,495.00
Availability: 15 weeks
 
Mounting 6" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
Compact Liquid Coriolis Meters with 0.1% Accuracy
FMC-5101LA
USD10,405.00
Availability: 13 weeks
 
Mounting ½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5102LA
USD10,940.00
Availability: 9 weeks
 
Mounting 1" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5103LA
USD12,460.00
Availability: 9 weeks
 
Mounting 1½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5104LA
USD15,960.00
Availability: 9 weeks
 
Mounting 2" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5105LA
USD19,790.00
Availability: 15 weeks
 
Mounting 3" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5106LA
USD34,540.00
Availability: 15 weeks
 
Mounting 4" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5107LA
USD44,540.00
Availability: 15 weeks
 
Mounting 6" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
Air/Gas
FMC-5501GA
USD6,785.00
Availability: 9 weeks
 
Mounting ½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5502GA
USD7,950.00
Availability: 9 weeks
 
Mounting 1" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5503GA
USD8,940.00
Availability: 9 weeks
 
Mounting 1½" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5504GA
USD11,485.00
Availability: 9 weeks
 
Mounting 2" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5505GA
USD15,075.00
Availability: 15 weeks
 
Mounting 3" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5506GA
USD24,190.00
Availability: 15 weeks
 
Mounting 4" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
FMC-5507GA
USD30,960.00
Availability: 15 weeks
 
Mounting 6" ANSI, Pressure Rating 16 bar (230 psi), Power 18 to 36 Vdc, Communication RS485 (RTU Modbus)
All amounts shown in USD
Note: Comes complete with operator’s manual.
NOTE: HEAVY WEIGHT - NO UPS - MOTOR FREIGHT ONLY!!! OVERWEIGHT SHIPPING CHARGES WILL APPLY FOR THIS PRODUCT. IF ORDERED ON-LINE INTERNET SALES WILL CONTACT YOU AFTER ORDER PLACEMENT UNLESS YOU OPT TO CHARGE FREIGHT TO YOUR CARRIER ACCOUNT.
For meters with other than ANSI flanges, change the “A” at the end of the model number to “D” for DIN flanges, “J” for JIS flanges or “S” for Sanitary Tri-Clamp flanges (liquid only),
no additional charge.
To replace the RS485 communications with HART communications add “-HART” to the model number,
for an additional charge.
For units with remote mounted display/transmitter add “-R” to the model number, for an additional charge.

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Accuracy select from:
1 for 0.1%
2 for 0.2%
5 for 0.5%

(2) Size Mounting select from:
1 for 1/2" (15 mm)
2 for 1" (25 mm)
3 for 1 1/2" (40 mm)
4 for 2" (50 mm)
5 for 3" (80 mm)
6 for 4" (100 mm)
7 for 6" (150 mm)

(3) Media Type select from:
G for Gas (0.5% Accuracy Only)
L for Liquid

(4) Flange Type select from:
A for ANSI
D for DIN
J for JIS
S for Sanitary (Liquid Only)

(5) Remote Display Option select from:
Nothing(leave field blank) for None
-R for Remote Mounted Display/Transmitter

(6) HART Communications Option select from:
Nothing(leave field blank) for RS485 Communications
-HART for HART Communications
Note: All combinations may not be valid, check spec sheet for valid part numbers.

Product Manuals:

Download Quick - Start Mass Flowmeter Manual
Download Coriolis Mass Flowmeters
We noticed you are from the US. Visit your local site for regional offers and live support.